Built to Every Standard That Matters

Our tanks aren't just compliant — they're certified by the same independent organizations that US installers, regulators, and insurance companies require. Every tank ships with documentation.

UL Listing — The Standard US Installers Require

UL (Underwriters Laboratories) listing is the baseline requirement for underground storage tanks in the United States. Our manufacturer's UL listings are confirmed and active.

UL

UL 58

Steel Underground Tanks for Flammable & Combustible Liquids

The primary certification for underground steel storage tanks in the United States. Our inner steel tank (ASTM A-36 carbon steel) is manufactured and tested to UL 58 standards, covering structural integrity, pressure testing, and material requirements.

What UL 58 Covers:
→ Structural integrity under load
→ Pressure testing (5 PSI pneumatic)
→ Material specification compliance
→ Quarterly unannounced factory inspections
UL Listed · EGHX Category
UL

UL 1746

External Corrosion Protection Systems for Steel USTs

Covers the high-density polyethylene (HDPE) secondary jacket surrounding the steel primary tank. This double-wall design prevents soil corrosion of the steel inner tank — a key EPA requirement since 1998. Our HDPE jacket is dielectric, non-corrosive, and 360° air-pressure testable, providing a fully defined annular space for leak monitoring.

What UL 1746 Covers:
→ HDPE jacket material and fusion-weld manufacturing
→ 360° air-pressure / soap leak testing
→ Vacuum-tested annular space (6 in. Hg)
→ Defined annular space for leak detection
HDPE Jacket · Defined Annular Space

API & ISO — Industry-Grade Manufacturing Standards

Beyond the tank-specific UL listings, our manufacturer holds the highest-tier quality certifications for oil & gas fabrication.

API Q1

API Spec Q1, 9th Edition

American Petroleum Institute quality management specification for design, manufacture, assembly, inspection, and delivery of welded tanks for the oil and gas industry. The gold standard for petroleum equipment manufacturing.

Certificate Q1-4457 · Valid Feb 2025 – Feb 2028
ISO 9001

ISO 9001:2015

International quality management system standard. Covers design, manufacture, assembly, inspection, and delivery with documented processes, continuous improvement, and third-party annual audits.

Certificate 5012 · Valid Feb 2025 – Feb 2028
API 650

API 650 Monogram

API License for welded steel plate tanks — fabricated steel plates and shop-built tanks per Appendix J. Demonstrates highest-grade welding and fabrication processes under API oversight.

License #650-0032 · Valid Feb 2025 – Feb 2028
PEI

Petroleum Equipment Institute

Member of PEI — the leading US association representing manufacturers and distributors of petroleum marketing equipment. PEI membership signals compliance with installation and operational best practices.

Member · US Industry Association
STI

Steel Tank Institute

Affiliated with STI — the Steel Tank Institute, which develops the industry standards referenced in EPA 40 CFR Part 280. STI certifications are the benchmark US tank installers and regulators recognize.

Industry Standards Body
SwRI

Southwest Research Institute

Independent third-party testing and validation. SwRI is a leading non-profit research organization that performs independent safety and performance testing on petroleum storage equipment.

Independent Testing Authority

EPA 40 CFR Part 280 Compliant

All Stealth Tanks USTs meet or exceed EPA federal underground storage tank regulations (40 CFR Part 280), including the 2015 updates requiring secondary containment, release detection, and corrosion protection. Our double-wall steel/HDPE construction satisfies all federal UST performance standards.

Secondary Containment
Double-wall construction with defined annular space satisfies EPA secondary containment requirement.
Corrosion Protection
UL 1746 HDPE outer jacket provides full corrosion protection. No cathodic protection required for the jacket.
Release Detection
Dedicated 2" NPT monitoring port enables electronic interstitial monitoring for immediate leak detection.
Spill & Overfill
42" sump collars and 22" manhole included for spill containment device and overfill protection installation.

Need Certification Documentation?

We can provide full UL listing certificates, API certification copies, and manufacturer documentation for your permit applications and TCEQ filings.

Request Documentation